Pure Storage FlashArray Troubleshooting: Capacity Alerts, Hosts Missing Volumes and Replication Lag
Quick, correct responses to the FlashArray alerts that page storage admins: effective capacity pressure, host connectivity, and async replication health.
Capacity and volumes
Look beyond raw numbers: in the Capacity view split volumes versus snapshots versus destroyed-but-not-eradicated data (the 24-hour eradication timer). Old snapshot policies are the usual hoarder - tighten or expire them. Plan eradication of destroyed volumes and compare the alert threshold against your real growth rate.
Confirm the volume is connected to the correct host or host group and that the host IQN or WWPNs match the array's view. Then rescan on the host - iscsiadm -m session -R for iSCSI, a fabric rescan for FC, reconnect for NVMe-oF. Multipathing should show all expected paths; if not, compare the host initiator list with the array's zoning and portal groups.
Replication and upgrades
Check replication link health and bandwidth in the array UI; one huge volume change can exceed the window. Verify the network path - MTU and firewalls on replication ports - and that the target is not saturated with its own I/O. If a policy repeatedly misses RPO, split the protection group or add bandwidth, and alert on lag, not just hard failure.